Skip to main content

THERMODYNAMICS MANUAL / B-TECH MECH / LANCASHIRE BOILER


AIM: - TO STUDY OF LANCASHIRE BOILER

APPARATUS: - A MODEL OF LANCASHIRE BOILER

THEORY: -
A LANCASHIRE BOILER IS A DOUBLE FIRE TUBE BOILER, INTERNALLY FIRED, HORIZONTAL, NATURAL DRAUGHT, AND NATURAL CIRCULATION TYPE OF BOILER. THIS BOILER IS VERY POPULAR AND RELIABLE BECAUSE OF SIMPLICITY OF DESIGN AND EASE OF OPERATION. THE BOILER HAS GOOD STEAMING QUALITY, AND COAL OF INFERIOR QUALITY CAN BE USED. IT HAS LOW MAINTENANCE AND OPERATING COST. THIS BOILER IS WIDELY USED IN SUGAR MILLS AND CHEMICAL INDUSTRIES. THIS BOILER IS USED WHERE LARGE RESERVOIR OF WATER AND STEAM ARE REQUIRED.

ITS MAIN FEATURES AND BRICKWORK SETTING IS SHOWN IN THE FIGURE. SEVERAL RINGS OF STEEL PLATES WE ARE EITHER WELDED OR RIVETED TO MAKE THE CYLINDRICAL SHELL OF SUITABLE DIMENSIONS. THIS BOILER HAS TWO PARALLEL FLUE PIPES THROUGH OUT THE LENGTH OF BOILER. BOTH THE FLUE TUBES, WHICH CARRY HOT GASES, LAY BELOW THE WATER LEVEL. TO ACCOMMODATE A GRATE OF SUFFICIENT AREA AND MINIMUM LENGTH, THESE FLUE TUBES ARE LARGER IN DIAMETER AT THE FRONT OF THE SHELL. TO CONTROL THE GAS FLOW AND TO CONTROL THE AMOUNT OF AIR ENTERING THE GRATE, DAMPERS ARE USED WHICH ARE PLACED IN PATH OF FLUE GASES.
COAL IS FED TO THE GRATES THROUGH FIRE DOORS. EACH OF THE FLUE TUBES HAS ITS OWN FURNACE WITH GRATES WHERE ITS COMBUSTION TAKES PLACE AND THE FLUE GASES RISING FROM THE FURNACES PASS OVER THE FIRE BRIDGE AND TRAVERSE ALONG THE HORIZONTAL PATH. THE HOT GASES LEAVING THE GRATE PASS UP TO THE BACK END OF THE TUBES AND THEN TRAVEL BACK FROM THE BOTTOM FLUE PASSAGE TO THE FRONT OF BOILER, WHERE THE GASES BIFURCATE AND PASS INTO THE TWO SIDE FLUES. THEREAFTER, THE GASES IN THE TWO SIDE FLUES ENTER THE COMMON FLUE AND FINALLY DISCHARGED TO THE ATMOSPHERE THROUGH CHIMNEY.

THE VARIOUS MOUNTINGS ARE:-

  • SAFETY VALVE: - THE FUNCTION OF SAFETY VALVE IS TO PERMIT THE STEM IN THE BOILER TO ESCAPE TO ATMOSPHERE WHEN PRESSURE IN THE STEAM SPACE EXCEEDS A CERTAIN SPECIFIED LIMIT. IT IS LOCATED ABOVE STEAM SPACE IN THE BOILER.
  • WATER LEVEL INDICATOR: - THE FUNCTION OF THE WATER LEVEL INDICATOR IS TO ASCERTAIN CONSTANTLY AND EXACTLY THE LEVEL OF WATER IN THE BOILER SHELL.
  • FUSIBLE PLUG: - ITS FUNCTION IS TO EXTINGUISH THE FIRE IN THE EVENT OF WATER LEVEL IN THE BOILER SHELL FALLING BELOW A CERTAIN SPECIFIED LIMIT.
  • PRESSURE GAUGE: - ITS FUNCTION IS TO SHOW THE PRESSURE AT WHICH THE STEAM IS BEING GENERATED IN THE BOILER.
  • BLOW OFF COCK: - THE BLOW OFF COCK SERVES TO DRAIN OUT THE WATER FROM THE BOILER AND TO DISCHARGE MUD SCALE ETC. PERIODICALLY OR TO EMPTY THE BOILER FOR INTERNAL CLEANING AND INSPECTION ETC.
  • FEED CHECK VALVE: - THE FEED CHECK VALVE ALLOWS THE FEED WATER TO PASS INTO THE BOILER AND TO PREVENT THE BACK FLOW OF WATER FROM THE BOILER IN THE EVENT OF FAILURE OF FEED PUMP.
HIGH STEAM & LOW WATER SAFETY VALVE:-
THE FUNCTION OF HIGH STEAM & LOW WATER SAFETY VALVE IS TWO FOLD: ---

  • IT BELOW OUT STEAM WHEN THE WATER LEVEL IN THE BOILER IS LOW.
  • IT BLOWS OUT STEAM IF THE STEAM PRESSURE IS HIGHER THAN THE WORKING PRESSURE.

MAN HOLE: - THESE ARE DOORS TO ALLOW MEN TO ENTER INSIDE BOILER FOR REPAIR OR INSPECTION.
THE ACCESSORIES USED IN THIS BOILER ARE:-


  • SUPER HEATER: - THE FUNCTION OF SUPER HEATER IS TO SUPERHEAT THE STEAM (USUALLY WET) GENERATED IN THE BOILER BY THE HEAT IN EXHAUST FLUE GASES.
  • ECONOMIZER: - ECONOMIZER IS USED TO RECOVER SOME OF THE HEAT FROM THE HEAT CARRIED AWAY IN THE FLUE GASES UP THE CHIMNEY & UTILIZED FOR HEATING THE FEED WATER TO THE BOILER.

Comments

Post a Comment

Popular posts from this blog

APRON MECHANISM IN LATHE

APRON MECHANISM IN LATHE Apron Mechanism: Apron is attached to the carriage and hangs over the front side of the lathe bed. It is useful in providing power and hand feed to both carriage and cross-slide. It is also used to provide power feed to the carriage during thread cutting through two half nuts. The construction of apron is shown in Fig. Fig - Apron Mechanism Construction Power is transmitted from the spindle to the lead screw and feed rod through the spindle gear and tumbler gear arrangement. A worm is mounted on the feed rod by a sliding key. The worm meshes with a worm gear on whose axis another gear G1 is attached. Gear G1 is attached to a small gear G2 by a bracket as shown in the diagram. Gear G4 is positioned to be in mesh with the rack gear always. Another gear G3 is mounted on the same axis of gear G4. The carriage hand wheel meant for longitudinal feed is attached to the gear G5 on the same axis. The gears G3 and G5 are always in mesh. The gear G...

DOM MANUAL / B-TECH / MECHANICAL / KUK - TO FIND THE SPEED AND TORQUE OF DIFFERENT GEARS IN AN EPICYCLIC GEAR TRAIN.

OBJECTIVE: TO FIND THE SPEED AND TORQUE OF DIFFERENT GEARS IN AN EPICYCLIC GEAR TRAIN. SPECIFICATIONS : 1.       GEAR TRAIN : SUN GEAR : 14 TEETH 2.       PLANT GEAR: 21 TEETH (2 NOS.) 3.       INTERNAL GEAR WITH : 56 TEETH TORQUE MEASUREMENT ·          INPUT TORQUE – MOTOR CURRENT CALIBRATED FOR MOTOR TORQUE. ·          PLANT CARRIER - PULLEY OF 50 MM DIA AND SPRING BALANCE. ·          INTERNAL GEAR - PULLEY, 120 MM DIA AND SPRING BALANCES. Ø   BOTH PULLEYS ARE PROVIDED WITH ROPE OF 12 Ø   MM DIA Ø   DRIVE MOTOR - 1HP DC MOTOR RPM MOTOR OPERATING ON 220 VOLTS Ø   50 HZ SUPLLY, DRIVING THE SUN GEAR. CURRENT(AMPS) TORQUE 1.00 0.5 1.20 1.5 1.40 2.5 ...

Boiler Mounting - Water Level Indicator

WATER LEVEL INDICATOR Function:   It is indicates the water level inside the boiler to an observer. Working:  The water of the boiler comes into the glass tube through the lower tube and the steam through the upper tube. The water then stands in the glass tube at the same level as in the boiler. Two cocks are used to control the passage of between the boiler and the glass tube while the third cock is in used to discharge some of the water from inside the boiler to see whether the gauge is in proper order or not. The glass tube is protected by means of a cover, made of specially toughened glass, which will prevent any accident that may happen due to breaking of glass tube. It is used for ordinary boilers. Image - Water Level Indicator Figure - Water Level Indicator