Skip to main content

Thermal Power Plant Working

THERMAL POWER PLANT WORKING

Thermal power plant use raw energy in fossil fuels (coal, oil, or gas) and convert it into mechanical energy through the expansion of steam from a high pressure in a suitable prime mover called steam turbine. Generator coupled with turbine produces electrical energy. Coal received from collieries in the rail wagons is mechanically unloaded by wagon Tippler and carried by Belt Conveyor system to Boiler Raw Coal Bunkers, after crushing in the Coal Crusher. The crushed coal, when not required for raw coal bunkers, is carried to cal storage area through belt conveyor and telescopic chute. The Raw Coal Chain Feeder regulates the quantity of coal from coal bunkers to Coal Mill, where coal is pulverized into the fine powder form. The pulverized coal is then sucked by Vapour Fan and finally stored in the pulverized Coal Bunkers. The pulverized coal is then pushed to the Boiler Furnace, which is comprised of water tube walls all around through which water circulates.

Pic - Working of Thermal Power Plant

This chemically treated water running through the walls of boiler furnace gets evaporated at high temperature into steam by getting furnace heat. This steam is further heated in the Super-Heaters. The dry steam at high temperature and pressure is fed to the turbine comprising of three cylinders .The thermal energy of this steam is utilized in turbine for rotating its shaft at high speed. The steam discharge from H.P. Turbine is returned to returned to Boiler Re-Heater & Tri flux for heating it once again before passing it to M.P./I.P. Turbine. The steam is then fed to the L.P. Turbine. Coupled to the turbine shaft is the rotor of the Generator, which produces electricity. The power from the generator is pumped into the Power Grid System through the Generator Transformer by stepping up the voltage. The steam after doing useful work in the turbine is condensed to water in Condenser for recycling in the boiler. The water is pumped to the Deaerator from condenser with the help of Condensate Extraction Pumps (C.E.P.) after being heated in the L.P. Heaters. From the Deaerator a hot water storage tank, the Boiler Feed Pump (B.F.P.) discharges feed water to the boiler at the Economizer after getting heated up in the H.P. heaters. Deaerator removes the dissolved oxygen air and other gases from the feed water.

Comments

  1. So informative! Thanks for sharing your knowledge! I Got more ideas. If you want to know more about steam turbine engines, just feel free to contact @ nconturbines.com. Thank you!

    ReplyDelete

Post a Comment

Popular posts from this blog

DOM MANUAL / B-TECH / MECHANICAL / KUK - TO FIND THE SPEED AND TORQUE OF DIFFERENT GEARS IN AN EPICYCLIC GEAR TRAIN.

OBJECTIVE: TO FIND THE SPEED AND TORQUE OF DIFFERENT GEARS IN AN EPICYCLIC GEAR TRAIN. SPECIFICATIONS : 1.       GEAR TRAIN : SUN GEAR : 14 TEETH 2.       PLANT GEAR: 21 TEETH (2 NOS.) 3.       INTERNAL GEAR WITH : 56 TEETH TORQUE MEASUREMENT ·          INPUT TORQUE – MOTOR CURRENT CALIBRATED FOR MOTOR TORQUE. ·          PLANT CARRIER - PULLEY OF 50 MM DIA AND SPRING BALANCE. ·          INTERNAL GEAR - PULLEY, 120 MM DIA AND SPRING BALANCES. Ø   BOTH PULLEYS ARE PROVIDED WITH ROPE OF 12 Ø   MM DIA Ø   DRIVE MOTOR - 1HP DC MOTOR RPM MOTOR OPERATING ON 220 VOLTS Ø   50 HZ SUPLLY, DRIVING THE SUN GEAR. CURRENT(AMPS) TORQUE 1.00 0.5 1.20 1.5 1.40 2.5 ...

Boiler Mounting - Water Level Indicator

WATER LEVEL INDICATOR Function:   It is indicates the water level inside the boiler to an observer. Working:  The water of the boiler comes into the glass tube through the lower tube and the steam through the upper tube. The water then stands in the glass tube at the same level as in the boiler. Two cocks are used to control the passage of between the boiler and the glass tube while the third cock is in used to discharge some of the water from inside the boiler to see whether the gauge is in proper order or not. The glass tube is protected by means of a cover, made of specially toughened glass, which will prevent any accident that may happen due to breaking of glass tube. It is used for ordinary boilers. Image - Water Level Indicator Figure - Water Level Indicator

Boiler Mounting - Blow off cock

BLOW OFF COCK Functions: ·         To discharge a portion of water when the boiler is in operation to blowout mud, scale or sediment periodically. ·         To empty the boiler, when necessary for cleaning, inspection & repair. ·         It is fitted on the boiler shell directly or to a short branch at the lowest part of the water space. This pipe is known as blow-down pipe. Working:   In order to operate the valve, the rectangular slot is brought in line with the passage of the body. This is possible by rotating the plug with the help of wheel. When the slot is placed in this position, the cock is opened and all the impurities, mud, sediments etc. Start flowing out of the boiler and they are removed. When the slot is brought at right angles to the passage of the body, the cock is closed. Image - Blow Off Cock Fig - Blow Off Cock...