THERMODYNAMICS MANUAL / B- TECH MECHANICAL/ BABCOCK & WILCOX BOILER


AIM: - TO STUDY OF LOCOMOTIVE BOILER

APPARATUS:-A MODEL OF LOCOMOTIVE BOILER.

THEORY:-
A FIRE-TUBE BOILER IS A TYPE OF BOILER IN WHICH HOT GASES FROM A FIRE PASS THROUGH ONE OR MORE TUBES RUNNING THROUGH A SEALED CONTAINER OF WATER. THE HEAT ENERGY FROM THE GASES PASSES THROUGH THE SIDES OF THE TUBES BY THERMAL CONDUCTION, HEATING THE WATER AND ULTIMATELY CREATING STEAM.
THE FIRE-TUBE BOILER DEVELOPED AS THE SECOND OF THE THREE MAJOR HISTORICAL TYPES OF BOILERS: LOW-PRESSURE TANK OR "HAYSTACK" THIS TYPE OF BOILER WAS USED ON VIRTUALLY ALL STEAM LOCOMOTIVES IN THE HORIZONTAL "LOCOMOTIVE" FORM. THIS HAS A CYLINDRICAL BARREL CONTAINING THE FIRE TUBES, BUT ALSO HAS AN EXTENSION AT ONE END TO HOUSE THE "FIREBOX". THIS FIREBOX HAS AN OPEN BASE TO PROVIDE A LARGE GRATE AREA AND OFTEN EXTENDS BEYOND THE CYLINDRICAL BARREL TO FORM A RECTANGULAR OR TAPERED ENCLOSURE.
A FIRE-TUBE BOILER IS SOMETIMES CALLED A "SMOKE-TUBE BOILER" OR "SHELL BOILER" OR SOMETIMES JUST "FIRE PIPE".


A LOCOMOTIVE BOILER IS A FIRE TUBE, INTERNALLY FIXED, HORIZONTALLY, MULTI TUBULAR BOILER. IT IS MAINLY EMPLOYED IN LOCOMOTIVES THROUGH IT MAY ALSO BE USED AS A STATIONARY BOILER. THE HOT GASES WHICH ARE GENERATED DUE TO BURNING OF THE COAL ARE DEFLECTED BY AN ARCH OF A FIRE BRICKS, SO THAT WALLS OF THE FIRE BOX MAY BE HEATED PROPERLY.
IN THE LOCOMOTIVE-TYPE BOILER, FUEL IS BURNT IN A FIREBOX TO PRODUCE HOT COMBUSTION GASES. THE FIREBOX IS SURROUNDED BY A COOLING JACKET OF WATER CONNECTED TO THE LONG, CYLINDRICAL BOILER SHELL. THE HOT GASES ARE DIRECTED ALONG A SERIES OF FIRE TUBES, OR FLUES, THAT PENETRATE THE BOILER AND HEAT THE WATER THEREBY GENERATING SATURATED ("WET") STEAM.

IN THE LOCOMOTIVE BOILER, THE SATURATED STEAM IS VERY OFTEN PASSED INTO A SUPERHEATER, BACK THROUGH THE LARGER FLUES AT THE TOP OF THE BOILER, TO DRY THE STEAM AND HEAT IT TO SUPERHEATED STEAM.

DRAUGHT FOR FIRE TUBE BOILERS, PARTICULARLY IN MARINE APPLICATIONS, IS USUALLY PROVIDED BY A TALL PARTIAL VACUUM. MODERN INDUSTRIAL BOILERS USE FANS TO PROVIDE FORCED OR INDUCED DRAUGHTING OF THE BOILER.


ANOTHER MAJOR ADVANCE IN THE ROCKET WAS LARGE NUMBERS OF SMALL-DIAMETER FIRE TUBES (A MULTI-TUBULAR BOILER) INSTEAD OF A SINGLE LARGE FLUE. THIS GREATLY INCREASED THE SURFACE AREA FOR HEAT TRANSFER, ALLOWING STEAM TO BE PRODUCED AT A MUCH HIGHER RATE. WITHOUT THIS, STEAM LOCOMOTIVES COULD NEVER HAVE DEVELOPED EFFECTIVELY AS POWERFUL PRIME MOVERS.

LOCOMOTIVE-TYPE BOILERS ARE ALSO USED IN TRACTION ENGINES, STEAM ROLLERS, PORTABLE ENGINES AND SOME OTHER STEAM ROAD VEHICLES. THE INHERENT STRENGTH OF THE BOILER MEANS IT IS USED AS THE BASIS FOR THE VEHICLE: ALL THE OTHER COMPONENTS, INCLUDING THE WHEELS, ARE MOUNTED ON BRACKETS ATTACHED TO THE BOILER. IT IS RARE TO FIND SUPERHEATERS DESIGNED INTO THIS TYPE OF BOILER, AND THEY ARE GENERALLY MUCH SMALLER (AND SIMPLER) THAN RAILWAY LOCOMOTIVE TYPES.

Comments

  1. What a great source! This post has successfully provided comprehensive information about boilers. Keep up the good work!

    ReplyDelete
  2. Can you tell me what will be the required heating surface area of 8 tons / hour steram boiler capacity.
    send me email on

    usmanrangooni.fbl@gmail.com

    ReplyDelete
  3. Amazing informative site! really technical work.

    ReplyDelete
  4. Electric heaters offer wider savings options like disconnecting the lower element. Electric ....
    electric boilers
    fire tube boiler
    concrete steam curing
    industrial boilers
    industrial boiler

    ReplyDelete
  5. Atico Export are the most affordable temperature measurement and calibration providers in india.

    ReplyDelete

Post a Comment

Popular posts from this blog

DOM MANUAL / B-TECH / MECHANICAL / KUK - TO FIND THE SPEED AND TORQUE OF DIFFERENT GEARS IN AN EPICYCLIC GEAR TRAIN.

OBJECTIVE: TO FIND THE SPEED AND TORQUE OF DIFFERENT GEARS IN AN EPICYCLIC GEAR TRAIN. SPECIFICATIONS : 1.       GEAR TRAIN : SUN GEAR : 14 TEETH 2.       PLANT GEAR: 21 TEETH (2 NOS.) 3.       INTERNAL GEAR WITH : 56 TEETH TORQUE MEASUREMENT ·          INPUT TORQUE – MOTOR CURRENT CALIBRATED FOR MOTOR TORQUE. ·          PLANT CARRIER - PULLEY OF 50 MM DIA AND SPRING BALANCE. ·          INTERNAL GEAR - PULLEY, 120 MM DIA AND SPRING BALANCES. Ø   BOTH PULLEYS ARE PROVIDED WITH ROPE OF 12 Ø   MM DIA Ø   DRIVE MOTOR - 1HP DC MOTOR RPM MOTOR OPERATING ON 220 VOLTS Ø   50 HZ SUPLLY, DRIVING THE SUN GEAR. CURRENT(AMPS) TORQUE 1.00 0.5 1.20 1.5 1.40 2.5 ...

Boiler Mounting - Water Level Indicator

WATER LEVEL INDICATOR Function:   It is indicates the water level inside the boiler to an observer. Working:  The water of the boiler comes into the glass tube through the lower tube and the steam through the upper tube. The water then stands in the glass tube at the same level as in the boiler. Two cocks are used to control the passage of between the boiler and the glass tube while the third cock is in used to discharge some of the water from inside the boiler to see whether the gauge is in proper order or not. The glass tube is protected by means of a cover, made of specially toughened glass, which will prevent any accident that may happen due to breaking of glass tube. It is used for ordinary boilers. Image - Water Level Indicator Figure - Water Level Indicator

Boiler Mounting - Blow off cock

BLOW OFF COCK Functions: ·         To discharge a portion of water when the boiler is in operation to blowout mud, scale or sediment periodically. ·         To empty the boiler, when necessary for cleaning, inspection & repair. ·         It is fitted on the boiler shell directly or to a short branch at the lowest part of the water space. This pipe is known as blow-down pipe. Working:   In order to operate the valve, the rectangular slot is brought in line with the passage of the body. This is possible by rotating the plug with the help of wheel. When the slot is placed in this position, the cock is opened and all the impurities, mud, sediments etc. Start flowing out of the boiler and they are removed. When the slot is brought at right angles to the passage of the body, the cock is closed. Image - Blow Off Cock Fig - Blow Off Cock...